Partial discharge detector and accessories

Current Location:HOME > En > Products > Partial discharge detector and accessories >

JF-A01D Single channel/JF-A04D 4 channels Partial discharge

Time:2020-12-22 13:28

Description:

The JF-A01D partial discharge detector is a new type of digital partial discharge detector developed by our company. It retains the advantages of the JF-A01N partial discharge detector, while reducing the size and optimizing performance. It uses a 10....

Detailed introduction
The JF-A01D partial discharge detector is a new type of digital partial discharge detector developed by our company. It retains the advantages of the JF-A01N partial discharge detector, while reducing the size and optimizing performance. It uses a 10.1-inch touch screen to replace the traditional The operation mode of the oscilloscope and the physical knob makes it more convenient to use.
 
The instrument adopts full touch screen operation, which not only improves the service life of the operation, but also has the following functions: one-key automatic calibration; high voltage test voltage divider ratio can be set; serial communication to upload test data. The instrument has the characteristics of high detection sensitivity, wide range of applicable test products, large dynamic range of the amplification system, multiple combinations of frequency bands (nine types), and strong anti-interference ability. This instrument is used in conjunction with a calibration pulse generator and an input unit. It is a practical partial discharge test instrument widely used by power departments, manufacturers, and scientific research institutes.
 
1. Measuring range
Number of channels: single-channel/four-channel (non-independent) equivalent capacitance range of testable products: 6pF~250uF measurement range: 0.1pC-10000nC amplifier:
(1) 3dB low frequency end frequency fL: 10, 20, 40kHz optional
(2) 3dB high frequency end frequency H: 80, 200, 300kHz optional
(3) Gain adjustment, coarse adjustment 6 gears, gain difference between gears 20±1dB, fine adjustment range>20dB
(4) Asymmetry of positive and negative impulse response <1dB
 
2. Display function
Display unit: 10.1 inch touch screen.
Zero mark system: the zero mark is consistent with all elliptical scanning frequencies
Time Window:
(1) Window width: adjustable, 5°~170° under 50Hz
(2) Window position: each window can be rotated 0°~170°
(3) The two time windows can be opened separately or simultaneously.
 
3.Ellipse scan time base:
(1) Frequency 50/60, 100, 150, 200, 400Hz
(2) Rotation: with 30° as the first gear, it can rotate 120°
(3) Working method: ellipse-sine wave-straight line 3. Measurement accuracy
Pulse peak display:
The touch screen display shows 1 decimal (greater than or equal to 10pC) and 2 decimals (less than 10pC).
Error: ±3% (in full scale) test voltage display:
(1) Range 150kV
(2) Input impedance: >1MQ
(3) Display: touch screen display, display 1 decimal
(4) Error: ±1%
Test frequency display: error: less than ±1%
Detection sensitivity: 0.01pC
 
4. Equipment structure
Size: 370mm (competitive), 460mm (depth), 215mm (high) Weight: about 12.5kg

 


Product consultation

Message box

  • Product:

  • Content:

  • Organization:

  • Name:

  • Tel:

  • E-mail:

  • Address: